Small-field radiotherapy photon beam output evaluation: Detectors reviewed

Lam, S.E. and Bradley, D.A. * and Khandaker, Mayeen Uddin * (2021) Small-field radiotherapy photon beam output evaluation: Detectors reviewed. Radiation Physics and Chemistry, 178. p. 108950. ISSN 0969-806X

Full text not available from this repository. (Request a copy)
Official URL: http://doi.org/10.1016/j.radphyschem.2020.108950

Abstract

Small fields (few cm and below) are being applied in therapy independently or as mm/sub-cm segments of larger fields. Included are intensity modulated radiotherapy (IMRT)/volumetric modulated arc therapy (VMAT), proton beam therapy, stereotactic radiosurgery (SRS)/stereotactic radiotherapy (SRT) and stereotactic body radiotherapy (SBRT). With an ability to more closely conform to the target volume, small field applications are nevertheless a challenge to accurate dose evaluation and treatment planning. The influencing factors include finite source size, steep dose gradients, charged particle disequilibrium, detector size and associated volume averaging effects, and changes in energy spectrum and associated dosimetric parameters. Accordingly, small-field dosimetric problems attract interest, not least in consideration of new generation small-volume detectors that promise to reduce energy and dose/dose-rate dependence, also perturbation effects. These include developments made prior to the IAEA-AAPM TRS-483 report on the dosimetry of small static fields in external beam radiotherapy. In present review, the small-field problem is revisited, attention being given to output factor determination using contemporary detectors (Gafchromic film, microDiamond-, diode- and plastic scintillation detectors), also optical fibre dosimeters developed by a University of Surrey/Malaysian Consortium, measurements being made in flattening (FF) and flattening filter-free (FFF) beams. Also included are the effects on output factors in using the daisy-chaining approach associated with the small-field detectors. A survey of small-size dosimeter research shows insignificant difference in small-field output values obtained via direct normalisation or daisy-chaining approach. For fields down to 1 × 1 cm2, microDiamond detector, stereotactic field diode (SFD) and EBT3 film show minor differences (< 3.4%) in the dose response ratio between flattened and non-flattened beams. Present review emphasizes the use of at least two dosimeters to address the variations in small-field dose response using the active micro-dosimeters or passive dosimeters discussed herein.

Item Type: Article
Uncontrolled Keywords: Small-field dosimetry; Output factor; FF; FFF; Optical fibre; Daisy chaining
Subjects: R Medicine > R Medicine (General) > R895-920 Medical Physics/Medical Radiology
Divisions: Others > Non Sunway Academics
Sunway University > School of Medical and Life Sciences [formerly School of Healthcare and Medical Sciences until 2020] > Centre of Biomedical Physics [wef 2021 changed to Research Centre for Applied Physics and Radiation Technologies and moved to SET ]
Depositing User: Dr Janaki Sinnasamy
Related URLs:
Date Deposited: 15 Feb 2021 05:14
Last Modified: 15 Feb 2021 05:14
URI: http://eprints.sunway.edu.my/id/eprint/1584

Actions (login required)

View Item View Item