GeB flat fibre TL dosimeters for in-vivo measurements in radiosurgery

Alyahyawi, A. and Dimitriadis, A. and Nisbet, Andrew and Bradley, D.A. * (2021) GeB flat fibre TL dosimeters for in-vivo measurements in radiosurgery. Radiation Physics and Chemistry, 178. p. 108973. ISSN 0969-806X

Full text not available from this repository. (Request a copy)
Official URL: http://doi.org/10.1016/j.radphyschem.2020.108973

Abstract

Noting an increase in demand for procedures involving clinical radiosurgery we seek to develop a high spatial resolution thermoluminescence dosimeter (TLD) to allow conduct of in vivo dose verification measurements. An associated need is for a dynamic dose range exceeding that of the well-established LiF (Mg,Ti) phosphor TLD-100, with in particular the latter being limited in performance at the elevated doses seen in radiotherapy. The work investigates the performance of a novel GeB co-doped Flat Fibre (GeB-FF) fabricated using the modified chemical vapour deposition (MCVD) process, the hollow capillary optical fibres (COF) produced from this being collapsed down into flat fibres (FF) to create strain-related defects. This process has already been demonstrated to increase the low dose sensitivity of optical fibres, notably at diagnostic x-ray potentials, with Minimum Detectable Dose (MDD) values of down to 0.1 μGy. The intent of present work, conducted as a component of a safety audit, part of the hospital periodic radiation protection quality assurance program, has been to examine and compare the performance of the two forms of TL dosimeter, GeB-FF and TLD-100, measuring scattered radiation resulting from cranial cavity radiosurgery procedures. The dosimeters were placed on the neck, chest and pelvis of 20 patients. Using both types of dosimeter, raw dose values at each site show general accord (±3 mGy at 1 σ), covering mean doses ranging from some 10 mGy to less than 1 mGy, representing doses of <1% to < 0.1% of prescribed dose at the treatment site. GeB-FF results uncorrected for energy response show absorbed doses greater than that using TLD-100, by factors of some 1.4, 1.2 and 1.5 for the pelvis, chest and neck respectively; energy corrections have been shown elsewhere to provide for much closer agreement.

Item Type: Article
Uncontrolled Keywords: Glass dosimeters; Stereotactic radiosurgery; GeB flat Fibres
Subjects: R Medicine > R Medicine (General) > R895-920 Medical Physics/Medical Radiology
Divisions: Others > Non Sunway Academics
Sunway University > School of Medical and Life Sciences [formerly School of Healthcare and Medical Sciences until 2020] > Centre of Biomedical Physics [wef 2021 changed to Research Centre for Applied Physics and Radiation Technologies and moved to SET ]
Depositing User: Dr Janaki Sinnasamy
Related URLs:
Date Deposited: 15 Feb 2021 05:20
Last Modified: 15 Feb 2021 05:20
URI: http://eprints.sunway.edu.my/id/eprint/1582

Actions (login required)

View Item View Item