Radiation dose homogeneity and critical organs in radiotherapy treatment of prostate cancer

Khairi, Y. and Omer, H. and Sulieman, A. and Deiab, N. and Mokhtar, Maha H. and Abolaban, Fouad A. and Alkhorayef, M. and Bradley, D.A. * (2021) Radiation dose homogeneity and critical organs in radiotherapy treatment of prostate cancer. Radiation Physics and Chemistry, 178. p. 109000. ISSN 0969-806X

Full text not available from this repository. (Request a copy)
Official URL: http://doi.org/10.1016/j.radphyschem.2020.109000

Abstract

Present study compares two different 3D radiotherapy techniques: three-dimensional conformal radiotherapy (3D-CRT) and 3D external-beam radiation dose fields from computerized treatment plans, produced for 30 prostate cancer patients. All of the patients were the subject of treatment at the National Cancer Institute in Egypt. Evaluation was made of dose homogeneity within the target volume and the dose to critical organs (organs at risk, OAR). The plans were based on CT scans, all for cases of localized prostate cancer (all stage T2N0M0), with the CT scans transferred to the treatment planning systems. Comparison of the two different 3D radiation techniques was made in terms of isodose distributions and dose-volume histograms. The percentage of the planning target volume receiving 95% (V95) and 107% (V107) of the prescribed dose were obtained. For the 3D-CRT technique, the mean values for these were respectively 90.6% and 5.7% while for the other 3D technique they were 94.9% and 3.8%. In examining the dose received by the OAR, use of the 3D-CRT technique was found to provide the preferred dose distribution, with much greater sparing of the bladder, rectum and head of both femora. For the rectum the mean V70, V75 and D95 values (the latter referring to doses to 95% of the treatment volume) for the 3D-CRT technique were 35.5%, 32.2% and 34% while for the other 3D technique these were 8.4%, 0.2% and 12% respectively. For the bladder, the mean V40 and V65 values obtained using the 3D-CRT technique were 80.8% and 74.9% while for the alternative 3D technique they were 20.4% and 17% respectively. Thus for the particular cohort, the 3D-CRT technique provided superior target coverage and reduction of dose to the OAR.

Item Type: Article
Uncontrolled Keywords: Prostate cancer; Treatment planning; 3D-CRT plans; Radiation risk
Subjects: R Medicine > R Medicine (General) > R895-920 Medical Physics/Medical Radiology
Divisions: Others > Non Sunway Academics
Sunway University > School of Medical and Life Sciences [formerly School of Healthcare and Medical Sciences until 2020] > Centre of Biomedical Physics [wef 2021 changed to Research Centre for Applied Physics and Radiation Technologies and moved to SET ]
Depositing User: Dr Janaki Sinnasamy
Related URLs:
Date Deposited: 11 Feb 2021 08:22
Last Modified: 11 Feb 2021 08:22
URI: http://eprints.sunway.edu.my/id/eprint/1573

Actions (login required)

View Item View Item